LED DIRECTIONAL MODULES
In addition to the 360° warning modules the lightbar may be equipped with a number of single head front-rear warning LED modules. These modules
are available in either the, PriZm 8-LED Reector, PriZm 3-LED Reector, 3-LED OLP OPTIX (dual stack 3-LED lightheads).
Operating Specications for front-rear module:
Operating Voltage: 10-16 VDC, Reverse Polarity Protection
Current Draw : Standby 16ma
Flashing Module:
Red/Amber - .25A avg @ 12.8 Volts
Blue/White - .4A avg @ 12.8 Volts
Steady Burn Module:
Red/Amber - .5A avg @ 12.8 Volts
Blue/White - .8A avg @ 12.8 Volts
Available Colors: Red , Blue, Amber, and White
The ash pattern for these modules is chosen by the following procedure:
Selecting Flash Patterns
The Pattern Select wire is the BLK/RED wire in the sixteen conductor lightbar control cable and is activated by momentarily touching the wire to
+power.
STEP 1
Power-up the lightbar and select the Level-1 ash mode by applying +power to the GRN/BLK wire in the 16 conductor control cable.
STEP 2
Observe the ashing pattern operation and determine which pattern is in operation for Level-1. Refer to Table 1A. This table shows the available
ash patterns. Note: the Factory Default is different and identied in the table for each of the ash mode Levels (L1, L2, L3). Once the ash pattern
has been determined, proceed to Step 3.
STEP 3
Scroll to the next ash pattern by momentarily holding the Pattern Select wire (BLK/RED) to +power for ~1 sec, until the lightbar LEDs switches ash
patterns, and then releasing it. This will step to the next pattern in numbered order as listed in Table 1A for the selected 3-Level mode. The new
pattern is automatically stored each time. Repeat this procedure for Level-2 and Level-3.
Note: HOLD the Pattern Select wire to the +POWER source for about 1 second and release then observe that the ash pattern has
changed to the next pattern in the sequence. To restore the Factory Default Emergency Warning Flash Patterns, hold the Pattern Select
wire on the +POWER source for ~four (4) seconds while L1, L2 or L3 is enabled.
Note: All control inputs are +power enabled.
Control Input Function Denitions
Wire Color Function Description
GRN/BLK Level 1 Level 1 Emergency Mode
WHT/BLK Level 2 Level 2 Emergency Mode
RED/BLK Level 3 Level 3 Emergency Mode
ORG/BLK Takedown lights Takedown Lights Steady Burn (overrides Takedown Flash)
BLU/BLK Rear Cut-Off Blacks-Out Rear Facing LEDs
GRN/WHT Front Cut-Off Blacks-Out Front Facing LEDs
RED/WHT Right Alley Light Right Alley Steady Burn (overrides Alley Light Flash)
BLK/WHT Left Alley Light Left Alley Steady Burn (overrides Alley Light Flash)
WHT ArrowStik Flash ArrowStik Flash (overrides L1, L2 & L3 for rear of light bar)
BLK/RED** Pattern Select Pattern Select for ArrowStik, L1, L2 & L3, enables test mode)
BLK Takedown Flash Enables Takedown Lights Wig/Wag Flash
RED* ArrowStik Left Left ArrowStik (overrides L1, L2 & L3 for rear of light bar)
GRN Cruise Lights End LEDs only (overridden by all other functions)
ORG* ArrowStik Right Right ArrowStik (overrides L1, L2 & L3 for rear of light bar)
BLU Light bar DIM Sets LED to Dim mode
BLU/WHT Alley Light Flash Enables Alley Light Wig/Wag Flash
5